The optimum design for the dose field uniformity of a 60Co irradiation facility
|更新时间:2023-03-30
|
The optimum design for the dose field uniformity of a 60Co irradiation facility
Journal of Radiation Research and Radiation ProcessingVol. 26, Issue 1, Pages: 5-8(2008)
作者机构:
1.中国科学院上海应用物理研究所 上海 201800
2.南华大学核科学技术学院 衡阳 421001
3.湖南省原子能农业应用研究所 长沙 410125
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
WANG Jianhua, QIU Xiaoping, LUO Zhiping, et al. The optimum design for the dose field uniformity of a 60Co irradiation facility. [J]. Journal of Radiation Research and Radiation Processing 26(1):5-8(2008)
DOI:
WANG Jianhua, QIU Xiaoping, LUO Zhiping, et al. The optimum design for the dose field uniformity of a 60Co irradiation facility. [J]. Journal of Radiation Research and Radiation Processing 26(1):5-8(2008)DOI:
The optimum design for the dose field uniformity of a 60Co irradiation facility
This work is dedicated to design the dose field uniformity of irradiation facility installed 576 cobalt sources sticks by use of Monte Carlo method and MATLAB language. By comparing calculations with measurements the further calculation of dose distribution in the irradiation facility was performed by setting 3200 tally points of irradiation doses. In order to obtain the optimum data employed in our study, numerous position adjustments of the cobalt source sticks were made to calculate the dose distribution of the irradiation facility. And it had been found that there was a good agreement between program calculations and the measurements. The dose uniformity of irradiation facility and the efficiency of energy usage will be greatly increased after adjusting the cobalt source sticks according to the calculated results.