JIN Cailing, XU Yujie, FAN Wo. Calculation of the internal radiation absorbed dose of 123I –Annexin V[J]. Journal of Radiation Research and Radiation Processing, 2006,24(3):175-177.
JIN Cailing, XU Yujie, FAN Wo. Calculation of the internal radiation absorbed dose of 123I –Annexin V[J]. Journal of Radiation Research and Radiation Processing, 2006,24(3):175-177.DOI:
To estimate absorbed doses by ,123,I-AnnexinV in human,125,I-AnnexinV was used as a radiotracer for measuring the distribution of radiolabeled Annexin V in mice. The standard Medical Internnal Radiation Dose (MIRD) method was used by Mirdose-3 software in dosimetry estimation. The results show that liver and kidney received 2.77×10,-3, and 2.71×10,-3, mGy/MBq, respectively. The red marrow received 1.78×10,-5, mGy/MBq, and the other organs received doses between 1.5×10,-4, and 10.5×10,-4,mGy/MBq.The effective dose was estimated at 5.55×10,-4, mSv/MBq. Human radiation dosimetry can be performed by the mice biodistribution data and important data for clinical safe trial of ,123,I-AnnexinV are provided.