Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus
|更新时间:2023-03-27
|
Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus
Journal of Radiation Research and Radiation ProcessingVol. 29, Issue 6, Pages: 371-376(2011)
作者机构:
1.苏州大学医学部放射医学与公共卫生学院 江苏省放射医学与防护重点实验室 苏州 215123
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
CHEN Guochong, LIU Wen, LIU Qingfang. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus. [J]. Journal of Radiation Research and Radiation Processing 29(6):371-376(2011)
DOI:
CHEN Guochong, LIU Wen, LIU Qingfang. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus. [J]. Journal of Radiation Research and Radiation Processing 29(6):371-376(2011)DOI:
Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus
The blood compatibility of the radiation sterilized disposable burette tansfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (,p,>,0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus.
Effect of gamma irradiation on three kinds of disposable medical protective clothing
Radiation technique provides fast and qualified sterilization service for disposable medical protective clothing to the fight against novel coronavirus pneumonia outbreak in Wuhan
Application of statistical process control in medical devices quality control of electron beam irradiation sterilization
Study on adaptation of radiation sterilization of 3M Steri-DrapeTM
RESEARCH ON DOSE SETTING FOR RADIATION STERILIZATION OF MEDICAL DEVICE
Related Author
No data
Related Institution
Suzhou CNNC Huadong Radiation Co., Ltd.
Shanghai Institute of Applied Physics, Chinese Academy of Science