Dosimetry uniformity in products irradiated stationarily by a single plate 60Co source
Environment Protection, Agriculture and Food Industry|更新时间:2023-03-30
|
Dosimetry uniformity in products irradiated stationarily by a single plate 60Co source
Journal of Radiation Research and Radiation ProcessingVol. 23, Issue 2, Pages: 123(2005)
作者机构:
1.西北核技术研究所 西安 710024
作者简介:
基金信息:
DOI:
CLC:
扫 描 看 全 文
GUO Pingwen, LI Songlan, ZHANG Lei, et al. Dosimetry uniformity in products irradiated stationarily by a single plate 60Co source. [J]. Journal of Radiation Research and Radiation Processing 23(2):123(2005)
DOI:
GUO Pingwen, LI Songlan, ZHANG Lei, et al. Dosimetry uniformity in products irradiated stationarily by a single plate 60Co source. [J]. Journal of Radiation Research and Radiation Processing 23(2):123(2005)DOI:
Dosimetry uniformity in products irradiated stationarily by a single plate 60Co source
To verify quality of irradiated products by a 3.9PBq single plate (1m×1m) source, Ag,2,Cr,2,O,7, dosimeters were used for measuring extreme doses in three kinds of Chinese medicine in a actual irradiation area of 1.4m×1.4m facing the source. The product cartons were piled on the irradiation area, and their positions were exchanged to improve dosimetry uniformity of the products. The dosimeters for monitoring the minimum dose were placed in center of the cartons. The minimum doses of the three kinds of Chinese medicine products were 2.98, 1.03 and 1.37kGy respectively, and the maximum doses were 4.61, 2.00 and 2.24kGy, respectively. The dosimetry uniformities were 1.55, 1.94 and 1.64, respectively, which are within the quality control requirement of ,U,≤2.