MIL−STD 883 Test Method 1019.5 and 1019.4 are respectively applied to test and validate typical CMOS devices of CC4069 (manufactured in two different technologies) and LC4007-RHA. Principles for the tests are given and test results are analyzed in detail, so as to realize under laboratory conditions the feasibilities and conservatisms of eatimating oxide trap charges and interface trap charges in space. The studies shows that, while the LC4007-RHA NMOS device passed the comparatively conservative 1019.4 tests, CC4069 devices failed in the 1019.5 tests, suggesting considerable interface trap charge build-up after high temperature annealing.
关键词
美军标1019.5互补型金属氧化物半导体器件辐射效应评估
Keywords
MIL−STD−883 Test Method 1019.5Complementary Metal−Oxide−Semiconductor Transistor (CMOS) deviceRadiation effect estimatiom