为评估机房辐射防护水平,依据机器的运行上限参数,运用相关文献报道的计算方法,对X射线初级和次级屏蔽层以及加速器防护门的屏蔽能力进行估算和分析。结果表明: 加速器机房四周墙体(除迷路内墙外)和天棚的设计厚度均大于理论计算厚度,表明机房的相应屏蔽层厚度设计可以满足15 MeV X射线加速器的防护标准及选定的剂量管理目标值;此外,机房防护门需增加8.3 mm 铅和6.9 cm含硼聚乙烯才能分别满足对X射线和中子的屏蔽要求。
Abstract
This paper is to evaluate and inspect the protective ability of the shielding walls and door with various thickness against the primary and secondary radiation coming from X-rays transferred by use of a medical accelerator according to the optimized parameters. The result indicates that the calculated thickness of the wall (except labyrinth interior wall) and accelerator facility roof could fit both the protection criterion and desired value of dose management for 15 MeV X-rays. Furthermore, the protective door should be added with a Pb layer of 8.3 mm and a polyethylene containing boron layer of 6.9 cm to meet the shielding requirement of X-rays and neutron, respectively.Cited
关键词
医用直线加速器屏蔽分析辐射防护
Keywords
Medical linear acceleratorShielding analysisRadiation protection
Radiation protection for foreign body salvage work in primary of nuclear power plant
Protective effect of Lanzhou lily polysaccharide fragment on X-ray-induced injury of bone marrow nucleated cells in mice
Central nervous system injury caused by space radiation and radiation protection
Research progress on the radioprotective effect of epigallocatechin gallate and its mechanism
Radioprotective effects of Angelica sinensis protein on mice
Related Author
No data
Related Institution
Jiangsu Nuclear Power Co. Ltd.
Medical College of Northwest Minzu University, Laboratory of Environmental Ecology and Population Health in Northwest Minority Regions of Northwest Minzu University
Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics
PLA Eastern Theater Air Force Hospital
Key Laboratory of Nuclear Technology Application and Radiation Protection in Astronautics (Nanjing University of;Aeronautics and Astronautics), Ministry of Industry and Information Technology